DocumentCode :
2245008
Title :
Detection of electrical tree initiation and assessment of shape of the developing tree using pattern recognition of partial discharge occurrence phase distribution
Author :
Komori, P. ; Nishiguchi, N. ; Hikita, M. ; Mizutani, Tomoko
Author_Institution :
Toba National College, Japan
fYear :
1993
fDate :
28-30 Sep 1993
Firstpage :
68
Lastpage :
69
Abstract :
We have constructed a PD pulse measurement and degradation diagnosis system (PDM/ES-I) of materials suffering partial discharge using a personal computer. We applied PDM/ES-I to electrical tree degradation in low density polyethylene. The PD pattern measured at a given aging time was compared with five standard normalized PD patterns which had been registered in advance as five representative degradation stages. Consequently, the pattern recognition method proved to allow an exact determination of the time when the tree was initiated. In addition, the result of assessment agreed well with the observed tree shape
Keywords :
ageing; automatic test equipment; insulation testing; partial discharges; pattern recognition; polyethylene insulation; trees (electrical); PD pulse measurement; PDM/ES-I; aging; degradation diagnosis; electrical tree; low density polyethylene; partial discharge; pattern recognition; personal computer; phase distribution;
fLanguage :
English
Publisher :
iet
Conference_Titel :
Partial Discharge, 1993., International Conference on
Conference_Location :
Canterbury
Print_ISBN :
0-85296-579-6
Type :
conf
Filename :
341432