• DocumentCode
    2245384
  • Title

    Automated analysis of contrast echocardiographic time-intensity curves to predict myocardial perfusion

  • Author

    Boyle, C. ; Saleh, R. ; Kemper, A. ; Nickerson, D. ; Parisi, A.

  • Author_Institution
    Veterans Adm. Med. Center, West Roxbury, MA, USA
  • fYear
    1988
  • fDate
    25-28 Sep 1988
  • Firstpage
    203
  • Lastpage
    206
  • Abstract
    It has been shown that the pattern of regional echocardiographic contrast enhancement bears a close relationship to regional perfusion. The authors describe a microcomputer-based method of analyzing circumferential and transmural myocardial echocardiographic contrast appearance and gray-level enhancement following microbubble injections. After digitizing the echocardiographic images, the pattern of contrast-intensity change in consecutive end-diastolic short-axis images of the left ventricle is determined for up to 32 circumferential regions and two myocardial layers. Parameters of the time-intensity curve for each circumferential myocardial region (such as appearance time, mean intensity, maximum intensity, and washout time) are being investigated as possible predictors of regional myocardial perfusion
  • Keywords
    acoustic imaging; cardiology; computerised picture processing; medical diagnostic computing; automated analysis; contrast echocardiographic time-intensity curves; gray-level enhancement; microbubble injections; microcomputer-based method; myocardial perfusion prediction; Biomedical imaging; Cardiology; Catheters; Data acquisition; Histograms; Image storage; Microcomputers; Myocardium; Time measurement; Video recording;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology, 1988. Proceedings.
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-8186-1949-X
  • Type

    conf

  • DOI
    10.1109/CIC.1988.72599
  • Filename
    72599