• DocumentCode
    226479
  • Title

    Boost power factor correction topology with average current control

  • Author

    Moldaschl, Jan ; Broulim, Jan ; Palocko, Lukas

  • Author_Institution
    Fac. of Electr. Eng., Dept. of Appl. Electron. & Telecommun., UWB, Pilsen, Czech Republic
  • fYear
    2014
  • fDate
    9-10 Sept. 2014
  • Firstpage
    213
  • Lastpage
    216
  • Abstract
    This paper presents experimental results of a power factor corrector (PFC) with the average current control. Nowadays, we need a power factor corrector for most switch mode power supplies. Usually, a boost corrector with the average current control is used. The average current control offers good noise immunity, small input ripple and stability. Main paper goal was explaining average current shaping technique. We designed PFC with average current control and tested it in range 50 - 500 W. The experimental results proved benefits and drawbacks of this control technique.
  • Keywords
    electric current control; power factor correction; switched mode power supplies; boost corrector; boost power factor correction topology; current control; power 50 W to 500 W; power factor corrector; switch mode power supplies; Current control; Inductors; Reactive power; Resistors; Total harmonic distortion; Transistors; Voltage control; CCM; PFC; average current control; continuous conduction mode; power factor corrector;