Abstract
Unbalanced or non-linear loads result in distorted stator currents and electromagnetic torque pulsations in stand-alone doubly fed induction generators (DFIGs). This study proposes the use of a proportional-integral repetitive control (PIRC) scheme so as to mitigate the levels of harmonic and unbalance at the stator terminals of the DFIG. The PIRC is structurally simpler and requires much less computation than existing methods. Analysis of the PIRC operation and the methodology to determine the control parameters is included. Simulation study as well as laboratory test measurements demonstrate clearly the effectiveness of the proposed PIRC control scheme.
Keywords
PI control; asynchronous generators; machine control; stators; torque; voltage control; PIRC; control parameters; electromagnetic torque pulsations; proportional-integral repetitive control; stand-alone doubly fed induction generators; unbalanced stator voltage mitigation;