• DocumentCode
    22753
  • Title

    Mitigation of distorted and unbalanced stator voltage of stand-alone doubly fed induction generators using repetitive control technique

  • Author

    Feng Wei ; Xinan Zhang ; Vilathgamuwa, D.M. ; San Shing Choi ; Shuai Wang

  • Author_Institution
    Sch. of Electr. & Electron. Eng., Nanyang Technol. Univ., Singapore, Singapore
  • Volume
    7
  • Issue
    8
  • fYear
    2013
  • fDate
    Sep-13
  • Firstpage
    654
  • Lastpage
    663
  • Abstract
    Unbalanced or non-linear loads result in distorted stator currents and electromagnetic torque pulsations in stand-alone doubly fed induction generators (DFIGs). This study proposes the use of a proportional-integral repetitive control (PIRC) scheme so as to mitigate the levels of harmonic and unbalance at the stator terminals of the DFIG. The PIRC is structurally simpler and requires much less computation than existing methods. Analysis of the PIRC operation and the methodology to determine the control parameters is included. Simulation study as well as laboratory test measurements demonstrate clearly the effectiveness of the proposed PIRC control scheme.
  • Keywords
    PI control; asynchronous generators; machine control; stators; torque; voltage control; PIRC; control parameters; electromagnetic torque pulsations; proportional-integral repetitive control; stand-alone doubly fed induction generators; unbalanced stator voltage mitigation;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IET
  • Publisher
    iet
  • ISSN
    1751-8660
  • Type

    jour

  • DOI
    10.1049/iet-epa.2012.0317
  • Filename
    6607121