Abstract :
Summary form only given. Thermal limitations of anode and cathode materials have shown to negatively impact operation of cold-cathode high-power microwave (HPM) sources. High pulse-repetition-frequency (PRF) operation of these devices exacerbates the problems already experienced in single shot mode where cold-cathode devices, specifically carbon fiber cathodes, are plagued by plasma formation on the anode and cathode followed by plasma/gas expansion that causes impedance collapse of the anode-cathode (A-K) gap. Hence, for frequency stable, repetitive operation, cold-cathode HPM devices require the use of thermally robust electrode materials and ultra-clean surfaces, leading to repeatable tube operation. This study focuses on burst-mode operation of an HPM sealed tube reflex-triode virtual-cathode-oscillator (vircator) for PRFs greater than 100 Hz. The vircator is driven by a 54 J, ~200 kV Marx generator with an approximate pulse width of 50 ns FWHM, and the vircator chamber has an empty volume of approximately 5 L with background pressures in the low 10-9 Torr. The anode materials studied include grade-1 titanium (TiG1), nickel 201L (Ni201L), and stainless steel 316L (SS316L); all in combination with a carbon fiber cathode. Empirically observed outgassing characteristics in conjunction with anode thermal modeling are presented under single-shot and rep-rate conditions. In addition, scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) techniques were employed to investigate anode and cathode surface integrities before and after vircator operation.
Keywords :
X-ray chemical analysis; cold-cathode tubes; nickel; pulse generators; scanning electron microscopy; stainless steel; titanium; triodes; vircators; EDX techniques; HPM sources; Marx generator; Ni; REP-rate operation; SEM techniques; Ti; anode materials; anode thermal modeling; burst-mode operation; carbon fiber cathodes; cathode materials; cold-cathode devices; energy-dispersive X-ray spectroscopy; grade-1 titanium; high pulse-repetition-frequency operation; high-power microwave sources; nickel 201L; scanning electron microscopy; sealed-tube reflex-triode vircator; stainless steel; virtual-cathode-oscillator; Anodes; Cathodes; Electron tubes; Steel;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Plasma Sciences (ICOPS) held with 2014 IEEE International Conference on High-Power Particle Beams (BEAMS), 2014 IEEE 41st International Conference on