DocumentCode
2279141
Title
Effect of the number of slots per pole on performance of permanent magnet generator direct-driven by wind turbine
Author
Liu, Ting ; Huang, Shoudao ; Deng, Qiuling ; Pu, Qingyun ; Huang, Keyuan
Author_Institution
Coll. of Electr. & Inf. Eng., Hunan Univ., Changsha, China
fYear
2011
fDate
20-23 Aug. 2011
Firstpage
1
Lastpage
4
Abstract
The PMSG (permanent magnet synchronous generator) with the rated power of 2MW which is driven directly without gear system is designed by equivalent magnetic-circuit method. In order to study the characteristics of permanent magnet generator directly driven by wind turbine with the rated power of 2MW, comparative study of the performance both of no load and rated load was studied under different design features such as the choice of the number of slots per pole and the pole embrace. The results based on FEA (Finite Element Analysis) show that the appropriate choice of slot number per pole and pole embrace has a significant effect on the performance of direct-drive permanent magnet generators. It can weaken the effect of no load voltage harmonics and help the direct-drive permanent magnet generators to obtain the better performance.
Keywords
electric drives; equivalent circuits; finite element analysis; magnetic circuits; permanent magnet generators; synchronous generators; wind turbines; FEA; direct-drive permanent magnet generators; equivalent magnetic-circuit method; finite element analysis; gear system; permanent magnet synchronous generator; power 2 MW; wind turbine; Forging; Harmonic analysis; Permanent magnets; Synchronous generators; Torque; Wind turbines;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2011 International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4577-1044-5
Type
conf
DOI
10.1109/ICEMS.2011.6073738
Filename
6073738
Link To Document