Title :
Impedance correction of one-port coaxial loads using reference air line
Author :
Jin-Seob Kang ; Jeong-Hwan Kim
Author_Institution :
Electromagn. Group, Korea Res. Inst. of Stand. & Sci., Taejon, South Korea
Abstract :
An impedance measurement method for one-port coaxial load using multiple reference air lines as the impedance standard and offset open and short as the reflection standard is presented in this paper. Measured impedances for termination and sliding load are presented and the measurement uncertainty is evaluated.
Keywords :
coaxial cables; electric impedance measurement; measurement standards; measurement uncertainty; impedance measurement; impedance standard; measurement uncertainty; offset open; offset short; one-port coaxial load; reference air line; reflection standard; sliding load; termination load; Calibration; Coaxial components; Frequency measurement; Impedance measurement; Measurement standards; Measurement uncertainty; Microwave measurements; Phase measurement; Reflection; Testing;
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
DOI :
10.1109/CPEM.2002.1034790