DocumentCode :
2283943
Title :
A voltage device used as high accurate voltage ratio standard
Author :
Tianxiao Yin ; Bo Liang ; Hao Wang ; Ruimin Liu
Author_Institution :
Nat. Inst. of Metrol., Beijing, China
fYear :
2002
fDate :
16-21 June 2002
Firstpage :
376
Abstract :
A voltage device based on connecting the voltage units in series-parallel configuration is proposed in this paper. It is similar to the well-known Hamon device (B.V. Hamon, J. Sci. Instr., vol. 31, pp. 450-453, 1954). It can be used to transfer the voltage to its multiple units for calibration of the voltage standard. This type of voltage device can also be used as the proportional arms of a voltage proportional bridge for obtaining the proportional transformation with high accuracy.
Keywords :
bridge circuits; calibration; transfer standards; voltage measurement; Hamon device; proportional transformation accuracy; series-parallel connected voltage units; voltage device; voltage proportional bridge arms; voltage ratio standard; voltage standard calibration; voltage transfer; Arm; Bridge circuits; Calibration; Defense industry; Equations; Joining processes; Metrology; Resistors; Thermal resistance; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
Type :
conf
DOI :
10.1109/CPEM.2002.1034879
Filename :
1034879
Link To Document :
بازگشت