• DocumentCode
    2284510
  • Title

    Irreversible magnet demagnetization analysis of IPM type BLDC motor by stator turn fault

  • Author

    Kim, Kyung-Tae ; Kim, Byeong-Woo ; Kang, Gyu-Hong

  • Author_Institution
    School of Electrical Eng., University of Ulsan, 102 Street Dae-hak, Nam-gu, Ulsan 680-749, Korea
  • fYear
    2012
  • fDate
    18-21 Sept. 2012
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    A stator turn fault in a symmetrical three-phase machine cause a large circulating current to flow and subsequently generated excessive heat in shorted turns, generate irregular control current of the three phase leads to demagnetization. In this paper, the effect of the circulating current in shorted turns on the demagnetization of PM and motor performance is analyzed by using the proposed analysis method. The simulated results on the demagnetization of PM at inter-turn fault (μ = 16.7) verified by experiment.
  • Keywords
    brushless DC motors; demagnetisation; permanent magnet motors; IPM type BLDC motor; interior permanent magnet motor; interturn fault; irregular control current; irreversible magnet demagnetization analysis; stator turn fault; symmetrical three-phase machine; Analytical models; Circuit faults; Demagnetization; Magnetic flux; Stator windings; Torque; Irreversible demagnetization of PM; circulating current; stator turn fault;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Strategic Technology (IFOST), 2012 7th International Forum on
  • Conference_Location
    Tomsk
  • Print_ISBN
    978-1-4673-1772-6
  • Type

    conf

  • DOI
    10.1109/IFOST.2012.6357695
  • Filename
    6357695