Abstract :
This paper considers the design of a modulator supply for RF tube applications. The supply is based on direct modulation of a series resonant parallel loaded power supply. The main aim of this work is to monitor semiconductor losses of the IGBT modules through calorimetry and the device temperature using high speed thermal imaging, during the pulse. The paper provides an overview of the technology and design used on the test rig prototype under study. The final experimental rig layout designed for internal device temperature and loss measurement will be presented. The overall goal of the work is to identify the limitations and reliability of the modulator technology proposed.
Keywords :
infrared imaging; insulated gate bipolar transistors; resonant power convertors; IGBT modules; high speed thermal imaging; long pulse resonant converter modulator; modulator technology; power device reliability assessment; series resonant parallel loaded power supply; Calorimetry; Insulated gate bipolar transistors; Monitoring; Power supplies; Pulse modulation; Pulse width modulation converters; Pulsed power supplies; Radio frequency; Resonance; Temperature measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
IEEE International Power Modulators and High Voltage Conference, Proceedings of the 2008
Conference_Location :
Las Vegas, NE
Print_ISBN :
978-1-4244-1534-2
Electronic_ISBN :
978-1-4244-1535-9
Type :
conf
DOI :
10.1109/IPMC.2008.4743630
Filename :
4743630
Link To Document :
بازگشت