• DocumentCode
    23119
  • Title

    Transient response optimisation for peak current mode buck converter in the application of dynamic voltage scaling

  • Author

    Shen Xu ; Yunpeng Yao ; Mingjian Kan ; Weifeng Sun

  • Author_Institution
    Nat. ASIC Syst. Eng. Res. Center, Southeast Univ., Nanjing, China
  • Volume
    7
  • Issue
    3
  • fYear
    2014
  • fDate
    Mar-14
  • Firstpage
    705
  • Lastpage
    712
  • Abstract
    For optimising the peak current mode buck converter´s transient response in the application of dynamic voltage scaling, an accurate small signal model of the converter under continuous conduction mode is built. The switch conduction loss, dead-time and other main parasitic parameters are considered in the presented model. Based on the model, a novel compensation network for the voltage loop is proposed, which eliminates the zero point of the voltage loop. The relationship between the gain of the proposed compensation network and the transient response of the output voltage relative to the reference voltage (Vref) at the input node of error amplifier is investigated. By this way, an optimal gain for the transient output voltage is obtained and the optimaltransient response without overshoot and oscillation relative to Vref is validated by the circuit simulations and tests.
  • Keywords
    amplifiers; circuit theory; power convertors; amplifier input node; conduction loss; continuous conduction mode; dynamic voltage scaling; peak current mode buck converter; small signal model; transient response optimisation;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IET
  • Publisher
    iet
  • ISSN
    1755-4535
  • Type

    jour

  • DOI
    10.1049/iet-pel.2013.0114
  • Filename
    6759609