DocumentCode :
2320567
Title :
DSP-based high-frequency HVDC source for verifying internal pressure of vacuum Chamber
Author :
Chen, Changlong ; Jiyan Zou
Author_Institution :
Electr. & Electron. Eng. Dept., DaLian Univ. of Technol., Dalian
fYear :
2008
fDate :
21-24 April 2008
Firstpage :
850
Lastpage :
853
Abstract :
Using the HVDC source, whose Voltage is just below the breakdown voltage of the vacuum chamber, we can realize the measuring of the internal pressure within the vacuum interrupters, using only electrical parameters. The HVDC described in this paper is a DSP-based high frequency system. The rectifier and IGBT inverter are controlled by a TMS320LF2407 DSP system, which has the hardware feature of providing a dead-band delay independent of the frequency of operation. This feature, together with the high speed of the DSP, allows the use of zero current resonant switching at a high power factor for frequencies up to 50 kHz. Resonant operation of the inverter is maintained by a simple digital PLL scheme implemented on the DSP. An EMI filter to compensate common mode current using high frequency transistors works just as a power active filter in the harmonic compensation in the power system. Experiment gives out the feasibility of the method on verifying internal pressure in vacuum interrupter.
Keywords :
HVDC power convertors; digital signal processing chips; invertors; rectifiers; vacuum interrupters; DSP-based high frequency system; DSP-based high-frequency HVDC source; EMI filter; IGBT inverter; TMS320LF2407 DSP system; breakdown voltage; common mode current; dead-band delay; digital PLL scheme; electrical parameters; harmonic compensation; high frequency transistors; internal pressure; power active filter; power system; rectifier; resonant operation; vacuum chamber; vacuum interrupters; zero current resonant switching; Active filters; Digital signal processing; Frequency; HVDC transmission; Interrupters; Inverters; Power harmonic filters; Power system harmonics; Resonance; Vacuum breakdown; DSP-based; EMI filter; HVDC; IGBT; internal pressure; vacuum chamber;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-1621-9
Electronic_ISBN :
978-1-4244-1622-6
Type :
conf
DOI :
10.1109/CMD.2008.4580417
Filename :
4580417
Link To Document :
بازگشت