• DocumentCode
    2321928
  • Title

    Time-resolved diode current density measurements for the Recirculating Linac injector

  • Author

    Haworth ; Smith, D.L. ; Mazarakis, Michael G. ; Poukey, J.W. ; Hasti ; Bennett, L.F. ; Lucero

  • Author_Institution
    Sandia Nat. Lab., Albuquerque, NM, USA
  • fYear
    1989
  • fDate
    0-0 1989
  • Firstpage
    82
  • Abstract
    Summary Form only given, as follows. Temporally and spatially resolved beam electron current density measurements at the anode foil of the Recirculating Linear Accelerator (RLA) 1.5-MV, 15-kA isolated-Blumlein injector have been made using a beam aperture technique. This method derives the beam current density radial profile from the magnitude of the beam current exiting from a range-thick aperture of varying radius centered on the beam axis and placed in contact with the downstream side of the planar anode foil. Successful application of this diagnostic requires axisymmetric beams having good shot-to-shot reproducibility. Experimental and simulation results have been compared.<>
  • Keywords
    electron accelerators; linear accelerators; particle beam diagnostics; 1.5 MV; Recirculating Linear Accelerator; anode foil; axisymmetric beams; beam aperture technique; beam electron current density measurements; diagnostic; isolated-Blumlein injector; radial profile; time resolved measurements; Electron accelerators; Linear accelerators; Particle beam measurements;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Plasma Science, 1989. IEEE Conference Record - Abstracts., 1989 IEEE International Conference on
  • Conference_Location
    Buffalo, NY, USA
  • Type

    conf

  • DOI
    10.1109/PLASMA.1989.166079
  • Filename
    166079