• DocumentCode
    232684
  • Title

    A current control method for quick-response and disturbances-rejection on SAPF

  • Author

    Hu Jin-gao ; Cheng Guo-yang ; Kuang Qiu-xia

  • Author_Institution
    Coll. of Electr. Eng. & Autom., FuZhou Univ., Fuzhou, China
  • fYear
    2014
  • fDate
    28-30 July 2014
  • Firstpage
    6926
  • Lastpage
    6930
  • Abstract
    Shunt active power filter with LCL output filter involves the tracking of transient current with high frequency harmonic components. The current control brings some complexity. This paper presents a kind of current control algorithm, which combines the triangle carrier comparison method with hysteresis control method. At the same time, the automatic self-correction of the grid-side disturbance while controlling current is discussed. The proposed algorithm is characterized by fast tracking of harmonic current, small computation capacity and easy implementation for engineering applications. Simulation and experiment verify the effectiveness of the proposed method.
  • Keywords
    active filters; electric current control; power grids; power harmonic filters; LCL output filter; SAPF; automatic self-correction; current control method; disturbances-rejection; engineering applications; grid-side disturbance; high frequency harmonic components; quick-response; shunt active power filter; transient current; triangle carrier comparison method; Active filters; Current control; Equations; Harmonic analysis; Mathematical model; Power grids; Power harmonic filters; Active Power Filter; Adaptive Compensation; Pulse Width Modulation; Regulator;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control Conference (CCC), 2014 33rd Chinese
  • Conference_Location
    Nanjing
  • Type

    conf

  • DOI
    10.1109/ChiCC.2014.6896141
  • Filename