• DocumentCode
    236013
  • Title

    A 600-V AC voltage amplifier for power measurements

  • Author

    Waltrip, B. ; Laug, O. ; Nelson, T.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    80
  • Lastpage
    81
  • Abstract
    A voltage amplifier comprised of three, cascaded, -10:1 gain sections has been developed to extend the voltage range of primary electric power calibrations from 120 V to 600 V over the 50 Hz to 400 Hz frequency range. The gain and phase errors of each amplifier section are continuously measured and corrected in-situ using a permuting impedance measurement technique. The amplifier design approach, measurement principles, and initial performance results are presented.
  • Keywords
    amplifiers; calibration; electric impedance measurement; error correction; measurement errors; measurement standards; power measurement; voltage measurement; AC voltage amplifier design approach; frequency 50 Hz to 400 Hz; gain error measurement; permuting impedance measurement technique; phase error measurement; power measurement; primary electric power calibration; voltage 120 V to 600 V; Decision support systems; Hafnium; Calibration; error correction; feedback amplifier; measurement standards; measurement techniques; power measurement; voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898268
  • Filename
    6898268