DocumentCode :
2360514
Title :
Estimation of pressure gradient images from velocity encoded MR acquisitions
Author :
Herment, A. ; Besson, G. ; Pellot-Barakat, C. ; Frouin, F.
Author_Institution :
LIF, Inserm, Paris
fYear :
2008
fDate :
14-17 Sept. 2008
Firstpage :
933
Lastpage :
936
Abstract :
Magnetic resonance imaging (MRI) offers the potential to estimate blood pressure gradients, by solving the Navier-Stokes model relating the haemodynamic pressure to the acceleration and velocity. Here we compared results directly obtained using acceleration encoded MR sequences with those calculated from MR velocity acquisitions available on clinical systems. We found that using velocity encoded data instead of acceleration encoded data significantly degrade gradient pressure images. Two experimental phantoms were used to separately evaluate the inertial and convective components of the acceleration. To improve the quality of the pressure gradient estimation, the regularization of the acceleration field, calculated from velocity encoded acquisitions was investigated. We also suggest to increase the temporal resolution while lowering spatial resolution to lessen motion artifacts.
Keywords :
Navier-Stokes equations; biological fluid dynamics; biomedical MRI; blood pressure measurement; cardiovascular system; medical image processing; phantoms; MR velocity acquisition; Navier-Stokes model; blood pressure gradient; haemodynamic pressure; magnetic resonance imaging; phantoms; velocity encoded MR acquisition; Acceleration; Blood pressure; Cardiology; Degradation; Encoding; Imaging phantoms; Magnetic resonance imaging; Motion estimation; Spatial resolution; Viscosity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Computers in Cardiology, 2008
Conference_Location :
Bologna
ISSN :
0276-6547
Print_ISBN :
978-1-4244-3706-1
Type :
conf
DOI :
10.1109/CIC.2008.4749196
Filename :
4749196
Link To Document :