• DocumentCode
    236440
  • Title

    Calibration of low-voltage AC-DC transfer standards at LNE in the frequency range from 10 Hz to 1 MHz

  • Author

    Khan, M.S. ; Poletaeff, Andre

  • Author_Institution
    Lab. Nat. de Metrol. et d´Essais (LNE), Trappes, France
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    512
  • Lastpage
    513
  • Abstract
    This paper describes the procedure recently introduced at LNE to calibrate low-voltage AC-DC transfer standards from 10 Hz to 1 MHz. Especially, a set of micropotentiometers is under development in order to take into account the voltage level dependence of the standards during the step-down procedure. Uncertainties of the order of 50 μV/V at 10 mV/1 MHz are expected. First measurement results are presented.
  • Keywords
    calibration; electric current measurement; measurement uncertainty; potentiometers; transfer standards; voltage measurement; LNE; calibration; frequency 10 Hz to 1 MHz; low-voltage AC-DC transfer standard; measurement uncertainty; micropotentiometer; step-down procedure; voltage level dependence; Calibration; Frequency response; Low voltage; Resistors; Standards; Uncertainty; AC-DC transfer; calibration; low-voltage standard; micropotentiometer; thermal converter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898484
  • Filename
    6898484