    Determining the influence of Time Constants in Maxwell Bridge

  • Author

    Yan Yang ; Qing Lu ; Lu Huang ; Wenjun Lu

  • Author_Institution
    Nat. Inst. of Metrol., Beijing, China
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    562
  • Lastpage
    563
  • Abstract
    This paper analyses the self-inductance measurement errors introduced by the time constants of the standard resistors and conductance used in Maxwell bridge, and proposes a common method to measure their time constants. After compensating, in the ranges from 1 mH to 100 H, the self-inductance measurement errors introduced by the time constants are less than 1 × 10-6 at 1 kHz.
  • Keywords
    bridge circuits; electric admittance measurement; inductance measurement; measurement errors; resistors; time measurement; Maxwell bridge; self-inductance measurement error; standard resistor; time constant measurement; Bridge circuits; Bridges; Electrical resistance measurement; Metals; Resistors; Standards; Time measurement; Conductance; Maxwell bridge; resistor; self-inductance; time constant;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898509
  • Filename