DocumentCode
236490
Title
Determining the influence of Time Constants in Maxwell Bridge
Author
Yan Yang ; Qing Lu ; Lu Huang ; Wenjun Lu
Author_Institution
Nat. Inst. of Metrol., Beijing, China
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
562
Lastpage
563
Abstract
This paper analyses the self-inductance measurement errors introduced by the time constants of the standard resistors and conductance used in Maxwell bridge, and proposes a common method to measure their time constants. After compensating, in the ranges from 1 mH to 100 H, the self-inductance measurement errors introduced by the time constants are less than 1 × 10-6 at 1 kHz.
Keywords
bridge circuits; electric admittance measurement; inductance measurement; measurement errors; resistors; time measurement; Maxwell bridge; self-inductance measurement error; standard resistor; time constant measurement; Bridge circuits; Bridges; Electrical resistance measurement; Metals; Resistors; Standards; Time measurement; Conductance; Maxwell bridge; resistor; self-inductance; time constant;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898509
Filename
6898509
Link To Document