Title
Uncertainty analysis in EVM measurement using a Monte-Carlo simulation
Author
Chihyun Cho ; Joo-Gwang Lee ; Jeong-Hwan Kim ; Dae-Chan Kim
Author_Institution
Center for Electromagn. Wave, Korea Res. Inst. of Stand. & Sci., Daejeon, South Korea
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
700
Lastpage
701
Abstract
An error vector magnitude (EVM) measurement method for W-CDMA source is proposed using a real time oscilloscope with traceability to SI unit. Also measurement uncertainty is evaluated based on a Monte-Carlo simulation, which takes into account the errors from the oscilloscope and signal processing. The measured EVM of a source at 900 MHz is 0.2535% ± 0.0057% at 95% confidence level.
Keywords
Monte Carlo methods; UHF measurement; code division multiple access; measurement errors; measurement uncertainty; oscilloscopes; signal generators; signal processing; EVM measurement uncertainty analysis; Monte-Carlo simulation; SI unit; VSG; W-CDMA source; error vector magnitude measurement method; frequency 900 MHz; oscilloscope; signal processing; vector signal generator; Jitter; Measurement uncertainty; Monte Carlo methods; Noise; Timing; Uncertainty; Measurement uncertainty; calibration; code division multiplexing; digital modulation; phase shift keying;