DocumentCode :
2370733
Title :
Design of modern EMC chambers for radiated EMC testing up to 18 GHz
Author :
Pues, Hugo F. ; Trautnitz, Friedrich W.
Author_Institution :
Emerson & Cuming Microwave Products N.V., Westerlo, Belgium
fYear :
1997
fDate :
18-22 Aug 1997
Firstpage :
72
Lastpage :
77
Abstract :
In the future, EMC measurements above 1 GHz will become mandatory. Currently, most newly realised full-compliance EMC chambers are already specified up to 18 GHz. However, whereas existing standards clearly specify the requirements between 26 MHz and 1 GHz, the standards for the higher frequency range are still in draft form. To construct such chambers, broadband EMC absorbers are required that are effective from 26 MHz to over 18 GHz. The absorber design needs to properly combine both low and high frequency concepts. Measurement results up to 18 GHz are shown for state-of-the-art anechoic EMC chambers for 3, 5 and 10 m test distance
Keywords :
anechoic chambers; electromagnetic compatibility; electromagnetic interference; measurement standards; testing; 10 m; 26 MHz to 1 GHz; 26 MHz to 18 GHz; 3 m; 5 m; EMC chambers design; EMC measurements; anechoic EMC chambers; broadband EMC absorbers; radiated EMC testing; standards; state-of-the-art; Anechoic chambers; Antenna measurements; Attenuation; Electromagnetic compatibility; Frequency measurement; IEC standards; Immunity testing; Performance evaluation; Receiving antennas; Standards development;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 1997. IEEE 1997 International Symposium on
Conference_Location :
Austin, TX
Print_ISBN :
0-7803-4140-6
Type :
conf
DOI :
10.1109/ISEMC.1997.667543
Filename :
667543
Link To Document :