EMI in a workstation server resulting from CPU clock harmonics was investigated. Mechanisms by which noise is coupled off the CPU PCB module were diagnosed from studies and measurements on the CPU PCB alone. A model was then developed. Modifications were made and tested in the fully functional system to support the model
Keywords
computers; electromagnetic interference; file servers; harmonics; printed circuits; workstations; CPU PCB module; CPU clock harmonics; EMI source identification; measurements; modelling; noise coupling; workstation server; Apertures; Clocks; Connectors; Electromagnetic compatibility; Electromagnetic interference; Frequency; Laboratories; Sun; System testing; Workstations;