• DocumentCode
    2374464
  • Title

    Identifying an EMI source and coupling path in a computer system with sub-module testing

  • Author

    Radu, S. ; Ji, Y. ; Nuebel, J. ; Drewniak, J.L. ; Van Doren, T.P. ; Hubing, T.H.

  • Author_Institution
    Dept. of Electr. Eng., Missouri Univ., Rolla, MO, USA
  • fYear
    1997
  • fDate
    18-22 Aug 1997
  • Firstpage
    165
  • Lastpage
    170
  • Abstract
    EMI in a workstation server resulting from CPU clock harmonics was investigated. Mechanisms by which noise is coupled off the CPU PCB module were diagnosed from studies and measurements on the CPU PCB alone. A model was then developed. Modifications were made and tested in the fully functional system to support the model
  • Keywords
    computers; electromagnetic interference; file servers; harmonics; printed circuits; workstations; CPU PCB module; CPU clock harmonics; EMI source identification; measurements; modelling; noise coupling; workstation server; Apertures; Clocks; Connectors; Electromagnetic compatibility; Electromagnetic interference; Frequency; Laboratories; Sun; System testing; Workstations;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 1997. IEEE 1997 International Symposium on
  • Conference_Location
    Austin, TX
  • Print_ISBN
    0-7803-4140-6
  • Type

    conf

  • DOI
    10.1109/ISEMC.1997.667562
  • Filename
    667562