• DocumentCode
    2393498
  • Title

    Adjustment of adaptive sum comb filter for PPG signals

  • Author

    Pilt, Kristjan ; Meigas, Kalju ; Ferenets, Rain ; Kaik, Jüri

  • Author_Institution
    Dept. of Biomed. Eng., Tallinn Univ. of Technol., Tallinn, Estonia
  • fYear
    2009
  • fDate
    3-6 Sept. 2009
  • Firstpage
    5693
  • Lastpage
    5696
  • Abstract
    AC component of photoplethysmography signal carries important information for diagnostics. Registered signal may be affected by noises, which are sharing the same bandwidth. Adaptive comb filter is used for the AC component extraction. Due to filter averaging behavior it decreases the signal shape difference between consecutive beats. Comb filter needs to be adjusted for PPG signal. Comb filter new weight values are determined through numerical computation. Experiments with generated photoplethysmographic signals were carried out to compare adjusted and non-adjusted adaptive sum comb filter.
  • Keywords
    adaptive filters; bio-optics; comb filters; medical signal processing; plethysmography; AC component extraction; PPG signals; adaptive sum comb filter; filter averaging; photoplethysmography; Algorithms; Diagnosis, Computer-Assisted; Humans; Photoplethysmography; Reproducibility of Results; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE
  • Conference_Location
    Minneapolis, MN
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-3296-7
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2009.5333539
  • Filename
    5333539