Title :
Pulsed Vacuum Diode Diagnostics at the Texas Tech University High Power Microwave Facility
Author :
Crawford, Mark ; Calico, Steve ; Kristiansen, M. ; Krompholz, H.
Author_Institution :
Pulsed Power Laboratory
Abstract :
The diagnostics used to measure the voltage and current of the vacuum diode used in the high power microwave generator at Texas Tech University are discussed. The current probe is a transmission line Rogowski coil that has demonstrated nanosecond risetinies and has an output proportional to the excitation current for approximately 70 nanoseconds. The voltage probe is a software compensated resistive divider.
Keywords :
Copper; Current measurement; Diodes; Petroleum; Probes; Pulse measurements; Resistors; Switches; Vacuum technology; Voltage;
Conference_Titel :
Pulsed Power Conference, 1991. Digest of Technical Papers. Eighth IEEE International
Conference_Location :
San Diego, CA, USA
Print_ISBN :
0-7803-0177-3
DOI :
10.1109/PPC.1991.733354