    The method of three-phase PV inverter has the deficiency such as wave distortion and long adjustment time. Aimed at this situation, we propose a modified fuzzy PID control strategy. According to the characteristics of the running, we devise a modified fuzzy PID controller parameter setting principle, which add the power coefficient to Fuzzy Inference Engine with the error and error rate, to make the dynamic and steady-state performances of the method superior. At last, the simulation and experiment results verifies the feasibility and effectiveness of the proposed method.
  • Keywords
    fuzzy control; fuzzy reasoning; invertors; solar cells; three-term control; fuzzy PID control segmentation; fuzzy PID controller parameter setting principle; fuzzy inference engine; steady-state performance; three-phase PV inverter; three-phase photovoltaic inverter; Educational institutions; MATLAB; Mathematical model; PV inverter; fuzzy PID; power coefficient; simulation;