    Identification and location of breakdown in windings

  • Author

    Gopalakrishnan, M. ; Paneerselvam, M.A. ; Kumaravelu, C. ; Shreeshankar, R.B. ; Jayashankar, V.

  • Author_Institution
    SVCE, India
  • fYear
    2003
  • fDate
    19-22 Oct. 2003
  • Firstpage
    518
  • Lastpage
    521
  • Abstract
    It is possible to estimate the location of the fault based on a study of the resonant frequencies of the winding current. It is shown that the nearest neighbourhood rule based on a clustering approach provides a good framework for fault location. Additional signal acquisition in the form of the tank current can considerably simplify the identification of a fault to ground. Experimental investigations are performed in order to identify and locate breakdown in windings.
  • Keywords
    electric breakdown; fault diagnosis; fault location; transformer windings; breakdown; clustering approach; fault location; identification; nearest neighbourhood rule; resonant frequencies; signal acquisition; tank current; windings; Circuit faults; Coils; Electric breakdown; Fault diagnosis; Fault location; Frequency estimation; Lightning; Power transformer insulation; Power transformers; Resonant frequency;