Abstract :
This work reports the results of a basic research regarding the study of Partial Discharge (PD) behaviour in a flat cavity when the insulation is subjected to a square voltage waveform and to two different PWM-like voltage waveforms. Tests were performed on CIGRE II specimens realised using polyimide film samples.
Keywords :
ageing; electric breakdown; organic insulating materials; partial discharges; polymer films; pulse width modulation; CIGRE II cells; PWM voltages; flat cavity; partial discharge patterns; polyimide film samples; square voltage waveform; Aging; Electrodes; Frequency; Insulation; Partial discharges; Polyimides; Pulse width modulation; Silicon compounds; System testing; Voltage;