DocumentCode
2455089
Title
A study of the high intensity discharge lamp-electronic ballast interface
Author
Fellows, Mark W.
Author_Institution
HID Lamp Dev., Philips Lighting Co., Bath, NY, USA
Volume
2
fYear
2003
fDate
12-16 Oct. 2003
Firstpage
1043
Abstract
New electronic ballasts for high intensity discharge lamps have been introduced. The purpose of this paper is to identify requirements of the ballast interface from the perspective of the lamp. Acceptable electronic ballasts for HID lamps will result in lamp performance with equivalent or better then ANSI compliant magnetic ballasts. This study addresses proper starting, run-up, and steady state operation of HID lamps on electronic ballasts. Resonant and pulse ignition, run-up current and voltage requirements, acoustic resonance effects, and electrode instabilities are covered. The paper concludes with a summary of ballast requirements necessary to provide long lamp life.
Keywords
acoustic resonance; discharge lamps; electric ignition; electrodes; lamp accessories; starting; ANSI compliant magnetic ballasts; HID lamp-electronic ballast interface; acoustic resonance; electrode instabilities; high intensity discharge lamp; pulse ignition; resonant ignition; run-up; starting; steady state operation; Acoustic pulses; Electronic ballasts; Electrons; Heating; High intensity discharge lamps; Ignition; Ionization; Magnetic resonance; Steady-state; Temperature;
fLanguage
English
Publisher
ieee
Conference_Titel
Industry Applications Conference, 2003. 38th IAS Annual Meeting. Conference Record of the
Print_ISBN
0-7803-7883-0
Type
conf
DOI
10.1109/IAS.2003.1257672
Filename
1257672
Link To Document