Abstract :
This study investigated the feasibility of using split-focused ultrasound transducers with mechanical rotation to do multi-direction heating for breast tumor thermal therapy. The driving frequency, radius of curvature, and side length of the rectangle spherical transducer are 0.5 MHz, 10 cm, and 7 cm, respectively. In order to alleviate the rib heating, the transducer was tilted be 45 degree relative to the muscle/bone interface, and its focal zone was shifted with 6 mm away from the center of the planning target volume (PTV). Based on the multi-focus temporal switching technique, strategies employing single transducer and multiple transducers were both evaluated. As a single transducer was used, the transducer was rotated sequentially to achieve a uniform heating from four planned positions with 90 degree apart. While in multiple ultrasound transducers cases, an appropriate arrangement was designed to have the same configuration of acoustic beams in the single-transducer case. Computer simulations and in vitro phantom had been studied for this ultrasound heating system. The results demonstrated the capacity of this system design; it was able to effectively shorten the treatment time by generating a larger thermal lesion through multi-focus switching and sparing the cooling interval through multidirectional sonications. This study indicated that by appropriate arrangement of a single or multiple split-focused transducers with mechanical rotation, it is very promising to implement multi-direction heating for breast tumor thermal therapy.
Keywords :
biomedical ultrasonics; biothermics; cancer; phantoms; rotation; surgery; tumours; ultrasonic transducers; breast tumor thermal surgery; focused ultrasound surgery; frequency 0.5 MHz; mechanical rotation; multidirection heating; multidirectional heating; multifocus temporal switching technique; muscle-bone interface; planning target volume; radius 10 cm; rectangle spherical transducer; rib heating; size 7 cm; split-focused ultrasound transducers; thermal lesion; ultrasound heating system; Acoustic transducers; Bones; Breast tumors; Frequency; Heating; Medical treatment; Muscles; Surgery; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2007. IEEE
Conference_Location :
New York, NY
ISSN :
1051-0117
Print_ISBN :
978-1-4244-1384-3
Electronic_ISBN :
1051-0117
Type :
conf
DOI :
10.1109/ULTSYM.2007.447
Filename :
4410020
Link To Document :
بازگشت