DocumentCode
2480901
Title
Application of order bi-cepstrum to gearbox fault detection
Author
Li, Hui ; Ai, Shufeng
Author_Institution
Dept. of Electromech. Eng., Shijiazhuang Inst. of Railway Technol., Shijiazhuang
fYear
2008
fDate
25-27 June 2008
Firstpage
1781
Lastpage
1785
Abstract
The order bi-cepstrum technique is introduced and applied effectively to gearbox faults diagnosis under run-up condition. This new method combines order tracking technique with bi-cepstrum analysis. The resampling signal can be obtained by resampling of the vibration signal that has been sampled in the time domain. Therefore, the time domain transient signal is changed into angle domain stationary signal. In the end, the resampled signals are processed by bi-cepstrum technique. The experimental results show that order bi-cepstrum technique can effectively diagnosis the faults of the bearing.
Keywords
cepstral analysis; fault diagnosis; gears; machine bearings; signal sampling; vibrations; bearing fault diagnosis; domain stationary signal; gearbox fault detection; gearbox fault diagnosis; order bi-cepstrum analysis; order tracking; time domain transient signal; vibration signal resampling; Condition monitoring; Fault detection; Fault diagnosis; Frequency; Hardware; Machinery; Shafts; Signal analysis; Signal processing; Signal sampling; Bearing; Faults diagnosis; Order tracking analysis; Signal processing; bi-cepstrum;
fLanguage
English
Publisher
ieee
Conference_Titel
Intelligent Control and Automation, 2008. WCICA 2008. 7th World Congress on
Conference_Location
Chongqing
Print_ISBN
978-1-4244-2113-8
Electronic_ISBN
978-1-4244-2114-5
Type
conf
DOI
10.1109/WCICA.2008.4593192