• DocumentCode
    2485708
  • Title

    Scanning electron microscopy characterization of connector failures

  • Author

    Marshall, James L.

  • Author_Institution
    Dept. of Chem./Mater. Sci., North Texas Univ., Denton, TX, USA
  • fYear
    1988
  • fDate
    9-11 May 1988
  • Firstpage
    192
  • Lastpage
    197
  • Abstract
    The characterization of connector failures by scanning electron microscopy/energy dispersive X-ray (SEM/EDX) is described. The advantages of SEM/EDX over optical inspection are discussed. Three types of failures are covered: (1) migration of base metal to the surface, leading to corrosion at the contact area; and (2) fretting corrosion; (3) microcracking at the surface or at a barrier layer, exposing the base metal
  • Keywords
    X-ray chemical analysis; electric connectors; failure analysis; scanning electron microscopy; EDX; SEM; characterization; connector failures; corrosion; energy dispersive X-ray; fretting corrosion; microcracking; migration of base metal; optical inspection; scanning electron microscopy; types of failures; Connectors; Copper; Scanning electron microscopy; Tin;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronics Components Conference, 1988., Proceedings of the 38th
  • Conference_Location
    Los Angeles, CA
  • Type

    conf

  • DOI
    10.1109/ECC.1988.12593
  • Filename
    12593