    Measurement of Magnetic Permeability Using a Differentially Excited Loop

  • Author

    Bartran, David S.

  • Author_Institution
    Exothermics Inc., Amherst, NH, USA
  • Volume
    51
  • Issue
    8
  • fYear
    2015
  • fDate
    Aug. 2015
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    A balanced stripline is used to provide differential excitation of a single-loop permeability measurement for increased bandwidth over dual-loop and improved sensitivity over single-loop induction methods. The proposed measurement is unique in permitting independent calibration of the permeance scale factor through a series of loop deflection tests. A simplified theoretical model of the measurement is presented together with an estimate of the expected measurement error for common-loop configurations.
  • Keywords
    calibration; magnetic permeability; magnetic permeability measurement; strip lines; balanced stripline; differential excitation; differentially excited loop; independent calibration; loop deflection testing; magnetic permeability; permeance scale factor; single-loop induction methods; single-loop permeability measurement; Calibration; Conductors; Frequency measurement; Magnetic flux; Magnetic resonance imaging; Permeability measurement; Stripline; Magnetic Films; Measurement Uncertainty; Permeability Measurement;