Title :
Effects of pressure-dependent segmental arterial compliance and postural changes on pulse wave transmission in an arterial model of the human upper limb
Author :
Xu, Ke ; Butlin, Mark ; Avolio, Alberto P.
Author_Institution :
Australian Sch. of Adv. Med., Macquarie Univ., Sydney, NSW, Australia
fDate :
Aug. 30 2011-Sept. 3 2011
Abstract :
With increasing interest in the effect of postural changes on arterial blood pressure and vascular properties, it is important to understand effects of pressure-dependent arterial compliance. This study investigates effects of pressure-dependent compliance on pulse wave velocity (PWVar), pressure wave shape, and transmission characteristics in an arterial model of the human arm from heart to radial artery from supine to standing. Estimated central pressure waveform was used as the input for the model, calculated using a validated transfer function (SphygmoCor, AtCor Medical) from recorded radial pulses in 10 healthy male subjects (53.8±7.9 years) during 0, 30, 60 and 90 degree head-up tilt. A 5-segment linear model was optimized using estimated central and recorded radial arterial pulse; each segment represented by an equivalent inductance, resistance and capacitance (compliance (C)) Pressure-dependent compliance (C(P)=a·eb·P was added to develop a nonlinear model, and the radial pulse calculated. Comparison of the radial pulse calculated by the linear and nonlinear models showed no statistical difference in systolic, diastolic, mean, and pulse pressure in any position of tilt. However, waveform shape was increasingly divergent at higher angles of tilt (RMS error 2.3±1.2 mmHg supine, 6.5±3.0 mmHg standing) as was PWVar (0% increase from supine to standing in the linear model, 16.7% increase in nonlinear model). Fourier analysis demonstrated peak amplitude of transmission being at higher frequencies and phase delay being lower in the nonlinear model relative to the linear model. Pressure-dependent arterial compliance, whilst having no effect on peak values of pressure, has significant effects on waveform shape and transmission speed, especially with a more upright position.
Keywords :
Fourier analysis; blood vessels; cardiovascular system; haemodynamics; Fourier analysis; arterial blood pressure; arterial model; human arm; human upper limb; postural change; pressure dependent segmental arterial compliance; pressure wave shape; pulse wave transmission; radial artery; Arteries; Blood pressure; Estimation; Humans; Mathematical model; Shape; Transfer functions; Arteries; Baroreflex; Blood Pressure; Blood Vessels; Computer Simulation; Electric Capacitance; Electrophysiology; Hemodynamics; Humans; Linear Models; Male; Middle Aged; Models, Cardiovascular; Posture; Pressure; Risk Factors; Systole; Time Factors; Upper Extremity;
Conference_Titel :
Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
Conference_Location :
Boston, MA
Print_ISBN :
978-1-4244-4121-1
Electronic_ISBN :
1557-170X
DOI :
10.1109/IEMBS.2011.6091592