DocumentCode :
2506497
Title :
Robot-assisted wrist training for chronic stroke: A comparison between electromyography (EMG) driven robot and passive motion
Author :
Hu, X.L. ; Tong, K.Y. ; Song, R. ; Zheng, X.J. ; Lui, K.H.
Author_Institution :
Dept. of Health Technol. & Inf., Hong Kong Polytech. Univ., Hong Kong
fYear :
2008
fDate :
19-22 Oct. 2008
Firstpage :
637
Lastpage :
641
Abstract :
The motor recovery procedure during robot-assisted wrist rehabilitation for persons after stroke has not been well studied previously. In this work, we carried out a comparative study on the training effects on 10 hemiplegic persons with chronic stroke between a wrist treatment assisted by an electromyography (EMG)-driven robotic system (interactive treatment, n=5, EMG group) and a wrist treatment assisted by a clinical robot system with continuous passive motion (n=5, passive group). Significant decreases (P < 0.05) in muscle spasticity were observed at the wrist joint in both the EMG and passive groups; and reduced muscle spasticity at the elbow joint were also obtained in the EMG group (P < 0.05). These spasticity decreases were associated with the reduction of EMG activation levels during the training. The EMG-driven robot-assisted training also improved the muscle coordination capability of the persons after stroke.
Keywords :
electromyography; medical robotics; patient rehabilitation; chronic stroke; elbow joint; electromyography; motor recovery; passive motion; robot assisted wrist training; Biomechatronics; Biomedical informatics; Elbow; Electromyography; Medical treatment; Muscles; Rehabilitation robotics; Robot kinematics; USA Councils; Wrist;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical Robotics and Biomechatronics, 2008. BioRob 2008. 2nd IEEE RAS & EMBS International Conference on
Conference_Location :
Scottsdale, AZ
Print_ISBN :
978-1-4244-2882-3
Electronic_ISBN :
978-1-4244-2883-0
Type :
conf
DOI :
10.1109/BIOROB.2008.4762807
Filename :
4762807