DocumentCode
2510167
Title
Effects of voltage unbalance on torque and current of the induction motors
Author
Guasch-Pesquer, Luis ; Youb, Lamia ; González-Molina, Francisco ; Zeppa-Durigutti, Edgardo-Renard
Author_Institution
Dept. d´´Eng. Electron., Electr. i Autom., Univ. Rovira i Virgili, Tarragona, Spain
fYear
2012
fDate
24-26 May 2012
Firstpage
647
Lastpage
652
Abstract
In order to analyze the effects of voltage unbalance on torque and current of the induction motors, there have been defined 32 unbalanced situations, with 8 different types of voltage unbalance, and four levels for the Voltage Unbalance Factor, measured with the Symmetrical Components method. For each unbalanced situation, both the Torque Ripple Factor and the Current Unbalance Factor are calculated to show the effects of voltage unbalance.
Keywords
induction motors; torque; current unbalance factor; induction motors; symmetrical components method; torque ripple factor; voltage unbalance; Induction motors; Load modeling; Power quality; Shape; Steady-state; Torque; Voltage measurement;