DocumentCode :
2512451
Title :
Induction motors with squirrel cage rotor, with IE2 efficiency level, up to 18.5 kW. methods for increasing the efficiency
Author :
Peter, Ioan
Author_Institution :
S.C. “Electroprecizia” S.A., Brasov, Romania
fYear :
2012
fDate :
24-26 May 2012
Firstpage :
550
Lastpage :
556
Abstract :
As it is known, the induction motors with squirrel cage rotor are classified according to IEC 60034-30:2008 in three efficiency classes: a. Standard Efficiency IE1; b. High Efficiency IE2; c. Premium Efficiency IE3. According to the ecodesign requirements, since 16 June 2011 motors shall not be less efficient than IE2 efficiency level. The motor manufacturers are obliged to comply with this requirement, developing the IE2 variant. This paper refers to the mode of execution of these motors, to the applied technical solutions and to the obtained results.
Keywords :
IEC standards; squirrel cage motors; IE1 standard efficiency; IE2 high efficiency level; IE3 premium efficiency; IEC 60034-30:2008; ecodesign requirements; induction motors; squirrel cage rotor; Bars; Induction motors; Lamination; Magnetic cores; Magnetic hysteresis; Rotors; Surface treatment;