DocumentCode :
25152
Title :
Modeling Load Uncertainty in Distribution Network Monitoring
Author :
Duy Thanh Nguyen
Author_Institution :
Tasmanian Networks, Hobart, TAS, Australia
Volume :
30
Issue :
5
fYear :
2015
fDate :
Sept. 2015
Firstpage :
2321
Lastpage :
2328
Abstract :
In this paper we describe an analytical method for estimating uncertainty in distribution loads, with applications to network monitoring and optimal meter placement. Our model works by assessing the impact of consumption aggregation from customers of different types, in order to determine the mean and variance of loading profile in each distribution transformer in the network. Such parameters are then adjusted by correlating with real-time information taken from the supervisory control and data acquisition system. Studies have been conducted on actual data to verify the proposed model and show its application for the optimal meter placement in distribution networks.
Keywords :
SCADA systems; distribution networks; power system measurement; distribution loads; distribution network monitoring; distribution transformer; load uncertainty; optimal meter placement; supervisory control and data acquisition system; Correlation; Load modeling; Mathematical model; Monitoring; Real-time systems; Standards; Uncertainty; Distribution network monitoring; energy billing data; load profiles; load uncertainty; optimal meter placement;
fLanguage :
English
Journal_Title :
Power Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8950
Type :
jour
DOI :
10.1109/TPWRS.2014.2364819
Filename :
6945387
Link To Document :
بازگشت