DocumentCode :
2516568
Title :
Three-Dimensional Position Sensitive CdZnTe Detector Array for PNNL
Author :
Zhang, Feng ; He, Zhong ; Seifert, Carolyn E.
Author_Institution :
Dept. of Nucl. Eng. & Radiol. Sci., Michigan Univ., Ann Arbor, MI
Volume :
6
fYear :
2006
fDate :
Oct. 29 2006-Nov. 1 2006
Firstpage :
3767
Lastpage :
3771
Abstract :
A new CdZnTe gamma-ray spectrometer system that employs two layers of modular detector arrays is being developed under the collaboration between the University of Michigan and PNNL. Each layer can accommodate up to three by three 3-dimensional position sensitive CdZnTe gamma-ray spectrometers. This array system is based on the newly developed VAS_UM/TAT4 ASIC readout electronics. Each of the nine detector modules consists of a pixellated CdZnTe detector and a VAS_UM/TAT4 ASIC front-end board. Each 1.5times1.5times1.0 cm3 CdZnTe detector employs an array of 11 by 11 pixellated anodes and a planar cathode. The energy depositions and 3-dimensional positions of individual interactions of each incident gamma ray can be obtained from pulse amplitude, location of each pixel anode and the drift time of electrons. This is the first system that multiple 3D CdZnTe detector modules can be tiled together to achieve detection volume greater than 40 cm3. This configuration allows the expansion of detector area to achieve higher detection efficiency while maintaining the excellent energy resolution. Experimental results of individual detectors and the array system are presented and discussed.
Keywords :
application specific integrated circuits; cadmium compounds; gamma-ray spectrometers; position sensitive particle detectors; readout electronics; semiconductor counters; 3D position sensitive detector; CdZnTe detector array; CdZnTe gamma-ray spectrometer; PNNL; VAS_UM/TAT4 ASIC front-end board; VAS_UM/TAT4 ASIC readout electronics; detection efficiency; energy resolution; pixellated CdZnTe detector; pixellated anodes; planar cathode; Anodes; Application specific integrated circuits; Cathodes; Collaboration; Gamma ray detection; Gamma ray detectors; Position sensitive particle detectors; Readout electronics; Sensor arrays; Spectroscopy;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Nuclear Science Symposium Conference Record, 2006. IEEE
Conference_Location :
San Diego, CA
ISSN :
1095-7863
Print_ISBN :
1-4244-0560-2
Electronic_ISBN :
1095-7863
Type :
conf
DOI :
10.1109/NSSMIC.2006.353813
Filename :
4179855
Link To Document :
بازگشت