Title :
Electrical structure of the lightning-channel corona sheath
Author :
Maslowski, Grzegorz ; Rakov, Vladimir A. ; Miki, Megumu
Author_Institution :
Dept. of Electr. & Comput. Eng., Rzeszow Univ. of Technol., Rzeszow, Poland
Abstract :
Expansion of positive (return-stroke) corona sheath inside the negative (leader) corona sheath is examined. It is shown that the positive corona sheath radius is smaller than that of the negative corona sheath. As a result, the overall corona sheath during the return-stroke stage is composed of two concentric zones: inner zone with net positive charge and outer one with negative charge. Corresponding radial electric field profiles are presented and compared to measurements.
Keywords :
lightning; concentric zones; electrical structure; lightning-channel corona sheath; negative corona sheath; net positive charge; positive corona sheath radius; radial electric field profiles; return-stroke stage; Computer industry; Corona; Electric breakdown; Electric variables measurement; Electromagnetic compatibility; Gaussian processes; Laboratories; Lightning; Optical propagation; Sparks;
Conference_Titel :
Electromagnetic Compatibility (APEMC), 2010 Asia-Pacific Symposium on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-5621-5
DOI :
10.1109/APEMC.2010.5475889