• DocumentCode
    252672
  • Title

    Optimization of valveless micropump for drug delivery

  • Author

    Jiaqi Wang ; Aw, Kean C. ; Sharma, Ritu

  • Author_Institution
    Dept. of Mech. Eng., Univ. of Auckland, Auckland, New Zealand
  • fYear
    2014
  • fDate
    13-16 April 2014
  • Firstpage
    86
  • Lastpage
    88
  • Abstract
    With controlled drug delivery system, appropriate and effective amount of drug can be precisely delivered at appropriate time by a micropump. This is achieved with the use of diffuser and nozzle elements that eliminate the need for valve mechanism simplifying the micropump design and fabrication. A preliminary valveless micropump prototype has been demonstrated and the systematic optimization to improve the performance at low Reynolds number (Re <; 100), typical in drug delivery system, is presented here.
  • Keywords
    bioMEMS; biodiffusion; drug delivery systems; microfabrication; micropumps; nozzles; optimisation; Reynolds number; controlled drug delivery system; diffuser; micropump design; micropump fabrication; nozzle elements; preliminary valveless micropump prototype; systematic optimization; valve mechanism; valveless micropump optimization; Clamps; Drug delivery; Market research; Micropumps; Prototypes; Strips; Drug delivery; IPMC; Micro-pump; Valveless;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nano/Micro Engineered and Molecular Systems (NEMS), 2014 9th IEEE International Conference on
  • Conference_Location
    Waikiki Beach, HI
  • Type

    conf

  • DOI
    10.1109/NEMS.2014.6908765
  • Filename
    6908765