DocumentCode
25310
Title
Minimum Variance Brain Source Localization for Short Data Sequences
Author
Ravan, M. ; Reilly, J.P. ; Hasey, G.
Author_Institution
Dept. of Electr. & Comput. Eng., McMaster Univ., Hamilton, ON, Canada
Volume
61
Issue
2
fYear
2014
fDate
Feb. 2014
Firstpage
535
Lastpage
546
Abstract
In the electroencephalogram (EEG) or magnetoencephalogram (MEG) context, brain source localization methods that rely on estimating second-order statistics often fail when the number of samples of the recorded data sequences is small in comparison to the number of electrodes. This condition is particularly relevant when measuring evoked potentials. Due to the correlated background EEG/MEG signal, an adaptive approach to localization is desirable. Previous work has addressed these issues by reducing the adaptive degrees of freedom (DoFs). This reduction results in decreased resolution and accuracy of the estimated source configuration. This paper develops and tests a new multistage adaptive processing technique based on the minimum variance beamformer for brain source localization that has been previously used in the radar statistical signal processing context. This processing, referred to as the fast fully adaptive (FFA) approach, can significantly reduce the required sample support, while still preserving all available DoFs. To demonstrate the performance of the FFA approach in the limited data scenario, simulation and experimental results are compared with two previous beamforming approaches; i.e., the fully adaptive minimum variance beamforming method and the beamspace beamforming method. Both simulation and experimental results demonstrate that the FFA method can localize all types of brain activity more accurately than the other approaches with limited data.
Keywords
array signal processing; electroencephalography; magnetoencephalography; medical signal processing; EEG signal; FFA approach; MEG signal; electroencephalogram; fast fully adaptive approach; magnetoencephalogram; minimum variance beamformer; minimum variance brain source localization; multistage adaptive processing; second order statistics; short data sequences; Array signal processing; Brain modeling; Electric potential; Electrodes; Electroencephalography; Noise; Vectors; Beamforming; brain source localization; electroencephalography (EEG); evoked potentials; fast fully adaptive (FFA) processing; magnetoencephalography (MEG);
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2013.2283514
Filename
6609076
Link To Document