DocumentCode
2539969
Title
A time domain measurements procedure of piezoelectric transformers equivalent scheme parameters
Author
Ozeri, S. ; Shmilovitz, D.
Author_Institution
Sch. of Electr. Eng., Tel Aviv Univ., Tel-Aviv
fYear
2006
fDate
21-24 May 2006
Lastpage
2284
Abstract
A time domain measurement based method of piezoelectric transformers model parameters is suggested. This method is simpler and assumes fewer measurements comparing to, commonly employed, admittance circle based procedures. In addition, the method proposed herein requires only standard laboratory equipment. An additional advantage of this method is the ability to test the PT at high voltage levels, providing better indication to the model parameter values that are in effect during actual operation of the device in a power converter
Keywords
equivalent circuits; network analysers; piezoelectric devices; power convertors; time-domain synthesis; transformers; model parameter; piezoelectric transformers; power converter; standard laboratory equipment; time domain measurements; Admittance; Capacitance; Dielectrics; Frequency; Magnetic resonance; RLC circuits; Time measurement; Transformers; Vibration measurement; Wavelength measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Circuits and Systems, 2006. ISCAS 2006. Proceedings. 2006 IEEE International Symposium on
Conference_Location
Island of Kos
Print_ISBN
0-7803-9389-9
Type
conf
DOI
10.1109/ISCAS.2006.1693076
Filename
1693076
Link To Document