    Impact of truncation to the reconstruction with a small number of projections

  • Author

    Yanfei Mao ; Zeng, Gengsheng L.

  • Author_Institution
    Dept. of Bioeng., Univ. of Utah, Salt Lake City, UT, USA
  • fYear
    2012
  • fDate
    Oct. 27 2012-Nov. 3 2012
  • Firstpage
    3461
  • Lastpage
    3467
  • Abstract
    Dedicated cardiac SPECT systems have the advantage of high speed and sensitivity at no loss or even a gain in resolution. The purpose of this paper is to investigate segmented parallel-hole collimation, develop a tailored Maximum-Likelihood Expectation-Maximization (ML-EM) algorithm for reconstructing truncated projections, and find the minimal number of view-angles required. We simulated and compared three image configurations, including two segmented-parallel-hole detectors based on the conventional and large detectors, and one small multi-detector. To study the effects of truncation and the number of angular sampling, the number of view-angles was varied from 10 to 60 and the truncation degree increased from 91% to 95%. For each view-angle, the root-mean-square error (RMSE) between the reconstructed image and the phantom was calculated and used to give a measure of the accuracy of the reconstructions. Distortion was observed from the shape difference maps of the heart. A tailored MLEM algorithm was used in the reconstruction, wherein the true-projection to forward-projection ratios outside of FOV were set to one instead of zero before backprojection. Finally, an NCAT phantom and GATE Monte Carlo simulation tool were used to verify the conclusions. Computer simulation results show that truncation has little effect on the reconstructed images when sufficient view angles are provided, while it affects the reconstruction with few number of views in terms of reducing contrast and introducing bias to the reconstructions. Based on visual inspection only, 10 view-angles is sufficient to reconstruct the image without shape distortion. To reconstruct both value and shape correctly, 20 view-angles is the minimum requirement for truncated projections. Two segmented conventional detectors are sufficient to reconstruct the image without distortion. Uniform angular sampling gives a considerable improvement in the image quality, but a small rotation is required.
  • Keywords
    Monte Carlo methods; cardiology; expectation-maximisation algorithm; image reconstruction; image sampling; image segmentation; mean square error methods; medical image processing; phantoms; single photon emission computed tomography; GATE Monte Carlo simulation; ML-EM algorithm; NCAT phantom; RMSE; angular sampling; dedicated cardiac SPECT systems; heart; image reconstruction; phantom; root-mean-square error; segmented parallel-hole collimation; segmented-parallel-hole detectors; tailored maximum-likelihood expectation-maximization; truncated projection reconstruction; view-angles;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC), 2012 IEEE
  • Conference_Location
    Anaheim, CA
  • ISSN
    1082-3654
  • Print_ISBN
    978-1-4673-2028-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2012.6551789
  • Filename
    6551789