Abstract :
Several techniques for measuring the RMS value of 1-600-mV signals are described and compared to existing thermal transfer standards. Differences between the techniques at 100 mV are typically within +or-20 p.p.m. in the audio-frequency range and within +or-100 p.p.m. out to 1 MHz. A new low-voltage thermal transfer standard has made it possible to compare thermal converters, micropotentiometers, and a digitally synthesized source to a precision of 1 p.p.m. The results indicate that micropotentiometers, are inherently more accurate transfer devices in the DC to 1-MHz frequency range than low-voltage TVCs (thermal voltage converters).<>
Keywords :
measurement standards; potentiometers; voltage measurement; 0 to 7 MHz; 1 to 600 mV; digitally synthesized source; low-voltage standards; micropotentiometers; thermal converters; thermal transfer standard; thermal transfer standards; thermal voltage convertor; Decision support systems; Frequency conversion; Frequency measurement; Instruments; Measurement standards; Measurement techniques; Signal resolution; Standards development; Uncertainty; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements, 1990. CPEM '90 Digest., Conference on
Conference_Location :
Ottawa, Ontario, Canada
Type :
conf
DOI :
10.1109/CPEM.1990.109925
Filename :
109925
Link To Document :
بازگشت