DocumentCode
2585077
Title
Measurement of a variable frequency drive loss and efficiency using both calorimeter and powermeter
Author
Gong, Xiaofeng ; Lu, Haihui ; Flek, Ondrej ; Wei, Lixiang ; Morris, Garron ; Lukaszewski, Richard A. ; Zhang, Shaofeng
Author_Institution
Rockwell Autom., USA
fYear
2012
fDate
28-31 May 2012
Firstpage
700
Lastpage
707
Abstract
Variable frequency drive efficiency plays an important role in green energy applications. However, how to accurately measure drive loss and efficiency is still a question to the industry. This paper reviews the powermeter method, calorimeter method, and factors that affect accuracy. After a calorimeter is constructed and calibrated, a variable frequency drive is tested using both methods. Test results are compared and uncertainty analysis is given.
Keywords
calorimeters; losses; power measurement; variable speed drives; calorimeter method; green energy applications; powermeter method; uncertainty analysis; variable frequency drive efficiency; variable frequency drive loss measurement; Accuracy; Heating; Loss measurement; Power measurement; Temperature measurement; Temperature sensors; Uncertainty;
fLanguage
English
Publisher
ieee
Conference_Titel
Industrial Electronics (ISIE), 2012 IEEE International Symposium on
Conference_Location
Hangzhou
ISSN
2163-5137
Print_ISBN
978-1-4673-0159-6
Electronic_ISBN
2163-5137
Type
conf
DOI
10.1109/ISIE.2012.6237174
Filename
6237174
Link To Document