• DocumentCode
    258670
  • Title

    Evaluation of pairwise calibration techniques for range cameras and their ability to detect a misalignment

  • Author

    Lejeune, Antoine ; Grogna, David ; Van Droogenbroeck, Marc ; Verly, Jacques

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., Univ. of Liege, Liege, Belgium
  • fYear
    2014
  • fDate
    9-10 Dec. 2014
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    Many applications require the use of multiple cameras to cover a large volume. In this paper, we evaluate several pairwise calibration techniques dedicated to multiple range cameras. We compare the precision of a self-calibration technique based on the movement in front of the cameras to object based calibration. While the self-calibration technique is less precise than its counterparts, it yields a first estimation of the transformation between the cameras and permits to detect when the cameras become mis-aligned. Therefore, this technique is useful in a practical situations.
  • Keywords
    calibration; cameras; misalignment detection; multiple range camera; object based calibration technique; pairwise calibration technique; self-calibration technique; Calibration; Cameras; Estimation; Noise; Real-time systems; Three-dimensional displays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    3D Imaging (IC3D), 2014 International Conference on
  • Conference_Location
    Liege
  • Type

    conf

  • DOI
    10.1109/IC3D.2014.7032596
  • Filename
    7032596