DocumentCode :
2589542
Title :
Modifying existing preheater systems for improved productivity and efficiency [cement industry]
Author :
Lang, Theo
Author_Institution :
Holderbank Manage. & Consulting Ltd., Switzerland
fYear :
1990
fDate :
22-24 May 1990
Firstpage :
373
Lastpage :
387
Abstract :
Three cases of preheater/precalciner modifications covering a production capacity ranging from 1500 to 4500 mt/d for plants in France, Canada and the USA are described. The first example deals with the addition of an RSP type furnace to an existing PREPOL-AT precalciner for capacity enhancement and improvement of circulating elements behavior within the kiln. The second covers the replacement of an ACL grate preheater by a one-stage PREPOL-AS calciner enabling low alkali clinker production from high alkali, high sulfur, high kerogen raw materials in an environmentally sound manner. The third example shows the replacement of two underdimensioned Fuller-SF-calciners of a two-string preheater kiln by one large FLS type SLC-S precalciner in connection with the installation of a 10-50% capacity range bypass system. All three kiln conversions have been basically successful and able to meet the expectations almost entirely. However, since they came onstream a comparatively short while ago, some optimization and fine tuning work still has to be completed
Keywords :
cement industry; Canada; France; PREPOL-AT precalciner; RSP type furnace; USA; capacity enhancement; cement industry; circulating elements; efficiency; fine tuning work; kiln; low alkali clinker production; preheater systems; productivity; ptimization; Cement industry; Cyclones; Filters; Furnaces; Kilns; Moisture; Production; Productivity; Raw materials; TV;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Cement Industry Technical Conference, 1990., XXXII, Record of Conference Papers., IEEE
Conference_Location :
Tarpon Springs, FL
ISSN :
1079-9931
Type :
conf
DOI :
10.1109/CITCON.1990.111063
Filename :
111063
Link To Document :
بازگشت