    A novel circuit for removing the entire current harmonic distortion generated by ohmic phase-cutting devices

  • Author

    Fathabadi, Hassan

  • Author_Institution
    Eng. Dept., Kharazmi Univ., Tehran, Iran
  • Volume
    6
  • Issue
    9
  • fYear
    2013
  • fDate
    Nov-13
  • Firstpage
    1786
  • Lastpage
    1791
  • Abstract
    In this study and for the first time, a novel harmonic remover circuit is presented that removes the entire current harmonic distortion generated by the phase-cutting devices, which have ohmic input impedance (ohmic phase-cutting devices) such as lighting dimmers. The presented circuit has been designed and an experimental prototype has been built in the laboratory. It has a very exact operation to remove the total harmonic distortion (THD). It really removes the entire harmonic and the THD% of the compensated device is equal to the THD% of the same device without any phase cutting, so if the THD% of the system without any phase cutting is zero then the THD% of the compensated device will also be zero. The real measurement and experimental results are presented to validate the theoretically results and make a comparison between the advantages of this work and other related works.
  • Keywords
    harmonic distortion; harmonics suppression; power supply circuits; THD; current harmonic distortion; harmonic remover circuit; lighting dimmers; ohmic input impedance; ohmic phase-cutting devices; total harmonic distortion;