• DocumentCode
    2606901
  • Title

    Experimental works and analysis for influence of stator slot number on performance of interior PM motor

  • Author

    Choi, Jang-Young ; Ko, Kyoung-Jin ; Jang, Seok-Myeong

  • Author_Institution
    Dept. of Electr. Eng., Chungnam Nat. Univ., Dae-jeon, South Korea
  • fYear
    2010
  • fDate
    9-12 May 2010
  • Firstpage
    1
  • Lastpage
    1
  • Abstract
    This paper deals with experimental works and analysis for influence of stator slot number on performance of interior PM (IPM) motor. First, for a conventional 6-pole IPM rotor, stators with 18, 27 and 36 slots satisfied with same required and restricted conditions are designed. And then, performances and parameters of each IPM motor such as cogging torque, torque ripple, d- and q- axis inductance, total harmonic distortion (THD) of back-emf, etc. are investigated using 2-d finite element analyses (FEA). Finally, test results such as d- and q- axis inductance, back-emf and efficiency measurements are given to confirm analysis results. It is concluded from the results obtained by this work that the influence of stator slot number on IPM motor behavior is very significant.
  • Keywords
    finite element analysis; harmonic distortion; permanent magnet motors; stators; torque; 6-pole IPM rotor; 6-pole IPM stators; THD; back emf; cogging torque; d-axis inductance; experimental works; interior PM motor performance; q-axis inductance; stator slot number; torque ripple; total harmonic distortion; Finite element methods; Forging; Harmonic analysis; Inductance; Induction motors; Performance analysis; Rotors; Stators; Torque; Total harmonic distortion;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Field Computation (CEFC), 2010 14th Biennial IEEE Conference on
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    978-1-4244-7059-4
  • Type

    conf

  • DOI
    10.1109/CEFC.2010.5481286
  • Filename
    5481286