Title :
Phase mask enhancement for multi-echo MR images using a novel denoising method based on tissue relaxation properties
Author :
Taejoon Eo ; Younguk Kim ; Jinseong Jang ; Dosik Hwang
Author_Institution :
Sch. of Electr. & Electron. Eng., Yonsei Univ., Seoul, South Korea
Abstract :
Multiple-echo magnetic resonance images are a series of images acquired at different echo times. Especially, phase images of multiple-echo images are often used to measure susceptibility of tissues. But these images tend to have a low SNR because high sampling rates are used to reduce the scan time. Conventional filters can effectively reduce noise, but introduce spatial artifacts. To obtain high-quality phase images without spatial artifacts, we developed new denoising method based on tissue relaxation properties. As a result, we could obtain high-SNR and high-resolution phase image and phase mask.
Keywords :
biomedical MRI; image denoising; image enhancement; medical image processing; CONVENTIONAL FILTERS; image denoising method; multiecho MR images; multiple echo magnetic resonance images; multipleecho images; novel denoising method; phase image resolution; phase images; phase mask; phase mask enhancement; spatial artifacts; tissue relaxation properties; Magnetic resonance imaging; Noise reduction; Signal resolution; Signal to noise ratio; Spatial resolution; Denoising; MRI; Multi-echo; Phase image; Phase mask; Tissue relaxation;
Conference_Titel :
Electronics, Information and Communications (ICEIC), 2014 International Conference on
Conference_Location :
Kota Kinabalu
DOI :
10.1109/ELINFOCOM.2014.6914356