Title :
Beam extraction system for the cooler injector synchrotron at IUCF
Author :
Kang, X. ; Berg, G.P.A. ; Friesel, D. ; Lee, S.Y. ; Sloan, T.
Author_Institution :
Cyclotron Facility, Indiana Univ., Bloomington, IN, USA
Abstract :
The Cooler Injector Synchrotron (CIS) being built at IUCF will serve as an injector for the existing IUCF Cooler Ring. The beam extraction from CIS and injection to the Cooler Ring include the the orbit bump, extraction kicker, septum magnet in the CIS ring, the transport beam line, and injection part to the Cooler ring. After extracted from CIS ring with a traveling wave fast kicker (15 mrad) and a Lambertsen septum, beams are transported by the beam line BL9 to the cooler injection point and injected into the cooler ring by a fast traveling wave injection kicker
Keywords :
beam handling equipment; particle beam extraction; proton accelerators; storage rings; synchrotrons; IUCF cooler injector synchrotron; Lambertsen septum; beam extraction system; cooler injection point; extraction kicker; fast traveling wave injection kicker; orbit bump; septum magnet; transport beam line; traveling wave fast kicker; Computational Intelligence Society; Costs; Cyclotrons; Fluctuations; Ion beams; Optical polarization; Particle beam injection; Particle beams; Solenoids; Synchrotrons;
Conference_Titel :
Particle Accelerator Conference, 1997. Proceedings of the 1997
Conference_Location :
Vancouver, BC
Print_ISBN :
0-7803-4376-X
DOI :
10.1109/PAC.1997.749613